We treat our customers as partners. Hybrid Solar Inverters in Pakistan. we welcome partpartnerships such as with the dealers and get the recognition necessary to spur the development of a strong network of community partners and social partners, and entrepreneurs and non-profits.
Hybrid Solar Inverter in Pakistan
HiSEL Power Global Family participation for building a sunnier future for their country.Hisel power deals all kind of Solar Inverters in Pakistan. Also use for home base and industrial commercial
Hybrid Solar Inverter in Pakistan
is use for saving an Electric city. If purchased a Hybrid Solar inveter from Hisel Power Then company gives the more benefit’s for our client. Hisel Hybrid solar Inverter in Pakistan restart auto while Ac is recovering.
Solar Hybrid Inverter in Pakistan performing a Good battery optimization also having a smart design of Battery.
- Pure sine wave inverter
- Surge capacity for inductive loads
- Built-in solar charger and configurable AC/solar input priority
- Compatible with grid voltage or generator power
- Smart battery charger design for optimized battery performance
- Overload, short-circuit, over temperature, low/high voltage protection
- Provides power for common appliances like lights, fans, TVs, computers, washing machines, refrigerators, etc.
MODEL | HI0182-IHWP | HI1624-IHWP | HI2424-IHWP | HI3248-IHWP | HI4048-IHWP |
---|---|---|---|---|---|
Rated Power | 800W | 1600W | 2400W | 3200W | 4000W |
INPUT | |||||
Voltage | 230 VAC | ||||
Selectable Voltage Range | 170-280 VAC (For Personal Computers); 90-280 VAC (For Home Appliances) | ||||
Frequency Range | 50 Hz/60 Hz (Auto sensing) | ||||
OUTPUT | |||||
AC Voltage Regulation (Batt. Mode) | 230 VAC ± 5% | ||||
Surge Power | 2000VA | 4000VA | 6000VA | 8000VA | 10000VA |
Efficiency (Peak) | 90% | 93% | |||
Transfer Time | 10 ms (For Personal Computers) ; 20 ms (For Home Appliances) | ||||
Waveform | Pure sine wave | ||||
BATTERY | |||||
Battery Voltage | 12 VDC | 24 VDC | 48 VDC | ||
Floating Charge Voltage | 13.5 VDC | 27 VDC | 54 VDC | ||
Overcharge Protection | 15 VDC | 30 VDC | 60 VDC | ||
SOLAR CHARGER & AC CHARGER | |||||
Max PV Array Open Circuit Voltage | 40VDC | 60VDC | 105VDC | ||
Standby Power Consumption | 1 W | 2 W | 2 W | ||
Max Solar Charge Current | 50A | 50A | 50A | ||
Max AC Charge Current | 10 A or 20 A | 20 A or 30 A | 60 A | ||
Max Charge Current | 50 A | 110 A | |||
PHYSICAL | |||||
Dimensions (DxWxH) | 95x240x316mm | 100x272x355mm | 120x295x468mm | ||
Net Weight (kgs) | 5.0 | 6.4 | 6.9 | 9.8 | 9.8 |
OPERATING ENVIRONMENT | |||||
Humidity | 5% to 95% Relative Humidity(Non-condensing) | ||||
Operating Temperature | 0°C – 55°C | ||||
Storage Temperature | -15°C – 60°C |